6ES7416-5HS06-0AB0西門子S7-400H CPU模塊
西門子S7-400系列CPU416模塊6ES7416-5HS06-0AB0正品
西門子S7-400冗余CPU6ES7416-5HS06-0AB0原裝中央處理器
6ES7416-5HS06-0AB0西門子S7-400CPU處理器模塊6ES74165HS060AB0
型號 ?6ES7416-5HS06-0AB0? 是 ?西門子 SIMATIC S7-400H 系列? 的 ?高端冗余 CPU?(CPU 416-5H),專為超高可用性控制系統(tǒng)設(shè)計。以下是深度解析:
| ?分段? | ?含義? |
|---|---|
| ?6ES7? | SIMATIC S7 系列自動化組件 |
| ?416? | CPU 性能等級(416為?高端級?,處理能力) |
| ?5H? |
?冗余標(biāo)識符?: - ?H? = 高可用性(High Availability) - ?5? = 集成 PROFIBUS/MPI 接口 |
| ?S06? |
?技術(shù)版本?: - ?S06? = V6.x 固件(支持 TIA Portal) |
| ?0AB0? |
?硬件版本代碼?: - ?0AB0? = 硬件版本05(支持更大內(nèi)存) |
| ?項目? | ?規(guī)格? |
|---|---|
| ?處理器架構(gòu)? | 雙核 RISC(冗余同步執(zhí)行) |
| ?工作內(nèi)存? | ?2.8 MB?(程序) + ?2.8 MB?(數(shù)據(jù)) |
| ?位指令執(zhí)行時間? | ?0.01 μs?(工業(yè)級頂尖速度) |
| ?最大I/O地址范圍? | ?128 KB?(輸入/輸出各64 KB) |
| ?通信接口? | 1× ?MPI?(187.5 Kbps) + 2× ?PROFIBUS DP?(12 Mbps) + 1× ?光纖同步接口? |
| ?冗余切換時間? | ?<100 ms?(無擾動切換) |
| ?支持模塊數(shù)量? | 最多 ?128個?(含信號模塊/功能模塊) |
| ?固件版本? | ≥ ?V6.0?(兼容 TIA Portal V13 SP1 及以上) |
| ?組件? | ?型號? | ?作用? |
|---|---|---|
| ?同步模塊? | ?6ES7968-1AA03-0XA0? | 通過光纖同步雙CPU數(shù)據(jù)(?≤5ms延遲?) |
| ?冗余電源? | ?6ES7407-0KA02-0AA0? | 雙路供電(24V DC或120/230V AC) |
| ?冗余系統(tǒng)軟件? | ?S7-H Systems Library? | 實(shí)現(xiàn)故障自動切換 |
| ?組件類型? | ?最小配置數(shù)量? | ?作用? |
|---|---|---|
| ?同步光纖? | 2根(≥10 m) | CPU間數(shù)據(jù)同步(?單模LC接口?) |
| ?冗余鏈接模塊? | 2個 | 擴(kuò)展機(jī)架間冗余通信(如 ?UR2-H?) |
| ?高可用軟件包? | 1套 | S7-REDCONNECT / S7-H Systems |
| ?LED? | ?狀態(tài)? | ?含義? |
|---|---|---|
| ?INTF(紅)? | 常亮 | 內(nèi)部錯誤(需讀取診斷緩沖區(qū)) |
| ?EXTF(紅)? | 閃爍 | I/O模塊故障 |
| ?FRCE(黃)? | 常亮 | 強(qiáng)制變量激活 |
| ?BUS(紅)? | 閃爍 | PROFIBUS總線通信中斷 |
| ?需求場景? | ?推薦方案? |
|---|---|
| 替換舊型號(CPU 414-4H) | ?6ES7414-5HM06-0AB0?(性能過渡方案) |
| 升級至新一代 | ?S7-1500 R/H?(如 6ES7518-4HP00-0AB0) |
| 擴(kuò)展安全功能 | 搭配 ?F-FM(456-1FH00-0AA0)? 模塊 |
The 6ES7416-5HS06-0AB0 is a Siemens SIMATIC S7-400H series fault-tolerant CPU module, designed for high-availability (HA) and redundancy in critical automation systems.
Manufacturer: Siemens
Series: SIMATIC S7-400H (High Availability)
Module Type: CPU 416-5H (Fault-Tolerant Central Processing Unit)
Order No.: 6ES7416-5HS06-0AB0
Firmware Version: V6.0 (as indicated by -0AB0)
? Redundant operation (two CPUs in H-system configuration)
? PROFIBUS-DP & PROFINET (PN) interfaces (for communication & I/O integration)
? High processing power (suitable for complex process control, e.g., PCS 7)
? Supports hot-swapping of redundant components (minimizes downtime)
? Integrated safety functions (for fail-safe applications)
| Feature | CPU 416-5H (6ES7416-5HS06-0AB0) | CPU 414-5H | Standard S7-400 CPUs |
|---|---|---|---|
| Redundancy | Yes (H-system) | Yes (H-system) | No |
| Perbance | High (faster scan times) | Medium | Depends on model |
| Interfaces | PROFIBUS + PROFINET | PROFIBUS + PROFINET | Varies |
| Use Case | Critical processes (e.g., power plants) | Medium HA needs | Non-redundant systems |
Process automation (oil & gas, chemical, pharmaceuticals)
Power generation & distribution (fail-safe control)
High-availability manufacturing systems
Newer version: Check for 6ES7416-5HS07-0AB0 (firmware V7.0) or later.
Compatible with: SIMATIC PCS 7, STEP 7 (TIA Portal with limitations), and HMI/SCADA systems.
Requires STEP 7 (Classic or TIA Portal) for programming.
Redundant setup needs two identical CPUs + synchronization modules (e.g., UR2-H rack).