浼婇爴UPS闆绘簮 EX UPS 鏄铇棩铇璘PS闆绘簮Pulsar 绯诲垪鐨勪竴閮ㄥ垎锛屽彲鐐烘湇鍕欏櫒銆佹暩(sh霉)鎿�(j霉)瀛樺劜銆佺恫(w菐ng)绲¤ō鍌�銆侀浕瑭� 鈥� VOIP銆侀啱(y墨)鐧傝ō鍌欏拰宸ユキ(y猫)鍔犲伐鎻愪緵杓冮珮鐨勫彲鐢ㄦ€�銆侀潏娲绘€у拰鏈€浣庣殑绺芥搧鏈夋垚鏈�銆備互濉斿紡鎴栧彲璁婄殑姗熸灦/濉斿舰寮忔彁渚涘湪绶氶洐杞夋彌淇濊銆�
浼婇爴 EX 鈥� 鐗规€�
?浠ュ寮忔垨姗熸灦/濉斿彲杞夋彌寮忔彁渚涳紙鍖呮嫭娣烘鏋跺紡锛�
?澶氳獮瑷€LCD椤ず锛屼究浜庢搷浣溿€佹脯閲忓€艰í鍟忓拰鑷畾缇╄ō缃�
?鐛ㄧ珛鎺у埗鐨勮几鍑烘彃搴ф彁渚涚敥璨犺嵎銆佺崹绔嬭ō鍌欑殑閬犵▼閲嶅暉鍜岄爢搴忛枊姗�
?鐢℉otSwap MBP瀵︾従(xi脿n)瀹屽叏鐔辨洿鎻涳紙鍙垎闆㈠紡缍慨鏃佽矾锛夛細涓嶇敤鍒囨柗闆绘簮灏卞彲鏇存彌UPS
?鐢║SB锛嬩覆琛岀鍙e拰鍌欓伕绠$悊鍗★紙Web/SNMP銆丆ontacts銆丮odBus锛夋彃妲藉鐝�(xi脿n)鍚岄鏈€浣抽浕婧愮鐞�
?閫氶亷鍦ㄧ窔闆欒綁鎻涙嫇鎾插付鑷嫊鏃佽矾銆�0.9鐨勮几鍑哄姛鐜囧洜鏁�(sh霉)鍜屽姞闀风殑閬嬭鏅傞枔鍙伕闋呮彁渚涙渶澶у彲鐢ㄦ€�
鎶€琛撴寚妯� 700 1000 - 1000 RT2U 1500 - 1500 RT2U 2200 3000 - 3000 XL
椤嶅畾鍔熺巼 (VA/W) 700 VA / 630 W 1000 VA / 900 W1 1500 VA / 1350 W1 2200 VA / 1980 W 3000 VA / 2700 W1
鍨嬪紡 灏忓瀷濉斿紡 灏忓瀷濉斿紡鎴� RT2U锛堝寮� / 姗熸灦 2U锛� RT2U锛堝寮� / 姗熸灦 2U锛夊拰RT3U 锛堝寮� / 姗熸灦 3U锛�
闆绘埃鐗规€�
绲愭 鍦ㄧ窔闆欒綁鎻涘付鑷嫊鏃佽矾鍜屽姛鐜囧洜鏁�(sh霉)鏍℃鍔熻兘
涓嶄娇鐢ㄩ浕姹犳檪鐨勮几鍏ラ浕澹撳拰闋荤巼鑼冨湇 100/120/140/160 V(2)鍒�284V 鈥� 40鍒�70 Hz 100/120/160/184 V(2)鍒�284V 鈥� 40鍒�70 Hz
杓稿嚭闆诲鍜岄牷鐜� 230 V锛堝彲瑾�(di脿o)绡€(ji茅)鍒�200/208/220/240/250 V锛�锛�50/60 Hz 鑷嫊閬告搰鎴栬畩闋诲櫒妯″紡 230 V锛堝彲瑾�(di脿o)绡€(ji茅)鍒�200/208/220/240 V锛�锛�50/60 Hz 鑷嫊閬告搰鎴栬畩闋诲櫒妯″紡
閫f帴浠�
杓稿叆 1鍊� IEC C14 (10 A) 鎻掑骇 IEC C20 (16A) 鎴朒otSwap MBP HW涓婄殑鎺ラ牠鎺掞紙纭竷绶氾級
杓稿嚭 6鍊� IEC C13 (10 A) 鎻掑骇 8鍊� IEC C13 (10A)鎻掑骇 + 1鍊� IEC C19 (16A)鎻掑骇
閬犵▼鎺у埗鐨凱owershare鎻掑骇 浜掔浉鐛ㄧ珛鐨�2绲勶細2 + 1 IEC C13 (10A) 鎻掑骇 浼婇爴EX涓婄偤2绲� 2 x IEC C13 (10A)鎻掑骇
甯禜otSwap MBP FR/DIN/BS/IEC/HW鐨勯檮鍔犺几鍑� 4 鍊� FR/Schuko 鎻掑骇鎴� 3 鍊� BS 鎻掑骇鎴� 6 鍊� IEC 10 A 鎻掑骇鎴栨帴闋帓锛圚W 鍨嬭櫉锛�
甯禙lexPDU FR/DIN/BS/IEC鐨勯檮鍔犺几鍑� 8 鍊� FR/Schuko 鎻掑骇鎴� 6 鍊� BS 鎻掑骇鎴� 12 鍊� IEC 10 A 鎻掑骇
闆绘睜
50%鍜�70%璨犺級鐨勫吀鍨嬪悗鍌欐檪闁�(6)锛屼紛闋揈X 3000 XL闄ゅ5
EX 16 鍒嗛悩 / 10 鍒嗛悩 18 鍒嗛悩 / 12 鍒嗛悩 13 鍒嗛悩 / 9 鍒嗛悩 17 鍒嗛悩 / 12 鍒嗛悩 15 鍒嗛悩 / 10 鍒嗛悩
EX+1鍊婨XB / 75 鍒嗛悩 / 50 鍒嗛悩 50 鍒嗛悩 / 35 鍒嗛悩 85 鍒嗛悩 / 60 鍒嗛悩 60 鍒嗛悩 / 40 鍒嗛悩
EX+4鍊婨XB / 250 鍒嗛悩 / 200 鍒嗛悩 180 鍒嗛悩 / 120 鍒嗛悩 285 鍒嗛悩 / 200 鍒嗛悩 190 鍒嗛悩 / 150 鍒嗛悩
闆绘睜绠$悊 鑷嫊姣忓懆娓│锛堢敤LCD椤ず灞忔垨鍦ㄦ墍鎻愪緵鐨勮粺浠朵腑瀹氭湡瑾�(di脿o)绡€(ji茅)锛�銆佽嚜鍕曡瓨鍒ュ閮ㄩ浕姹犲柈鍏� => 閫g簩(x霉)鍌欑敤鏅傞枔鏈€澶у寲锛嬫繁搴︽斁闆讳繚璀�
鎺ュ彛
鎸囩ず鐕堝拰椤ず 3鍊� LED + 鍙(di脿o)绡€(ji茅)寮忓瑾炶█椤ず锛� 椤ず娓噺鍊笺€佹帶浠跺拰瑷疆鑿滃柈鐨勮í鍟�
閫氫俊绔彛 1鍊� USB 绔彛 + 1鍊� RS232 涓茶绔彛鍜岀辜闆诲櫒瑙搁粸4 + 1鍊嬬敤浜庨仩绋嬮枊/闂滃拰绶婃€ュ仠姝㈢殑灏忓瀷鎺ラ牠鎺�
閫氫俊鍗℃彃妲� 1鍊嬫彃妲�锛屼緵 NMC Minislot 鍗★紙鍖呭惈鍦� Netpack 寮忎腑锛夋垨 NMC ModBus/JBus 鎴朚C Contacts/Serial浣跨敤
宸ヤ綔姊濅欢銆佹婧栧拰瑾嶈瓑
宸ヤ綔婧害鍜屽櫔鑱茬瓑绱� 0掳C to 40掳C, 閫g簩(x霉), 45 dBA
鎬ц兘锛嶅畨鍏ㄦ€э紞闆荤鍏煎鎬� IEC/EN 62 040-3 (VFI-SS-113), IEC/EN 62 040-1-1, IEC/EN 60 950-1 (RD), IEC/EN 62 040-2 C1 绱�
瑾嶈瓑 CE銆乀眉V GS銆丆B 鍫卞憡銆乧T眉V-US CE銆乀眉V銆丆B 鍫卞憡銆乁L
EX绯诲垪鍙冩暩(sh霉) |
|
---|---|
鍔熺巼绛夌礆 | 700-3000 VA |
椤嶅畾闆诲 | 220-240V |
闋荤巼 | 50/60 Hz |
閰嶇疆 | Rack/Tower |
鐢�(ch菐n)鍝佺郴鍒� | Pulsar |
UPS鍨嬭櫉 |
|
|||
---|---|---|---|---|
鍨嬭櫉鍒嗛 | 椤嶅畾瀹归噺 | 杓稿叆閫f帴 | 杓稿嚭閫f帴 |
|
|
锛堜紡瀹�/鐡︾壒锛� |
|
|
|
EATON EX 姗熸灦 |
|
|||
EX RT1000 | 1000 / 900 | C14 | (6) C13 |
|
EX RT15002U | 1500 / 1350 | C14 | (6) C13 |
|
EX 2200 RT2U | 2200 / 1980 | C20 | (8) C13, (1) C19 |
|
EX 2200 RT3U | 2200 / 1980 | C20 | (8) C13, (1) C19 |
|
EX 3000 RT2U | 3000 / 2700 | C20 | (8) C13, (1) C19 |
|
EX 3000 RT3U | 3000 / 2700 | C20 | (8) C13, (1) C19 |
|
|
|
|
|
|
|
|
|||
EATON EX 濉斿紡 |
|
|||
EX T700 | 700 / 630 | C14 | (6) C13 |
|
EX T1000 | 1000 / 900 | C14 | (6) C13 |
|
EX T1500 | 1500 / 1350 | C14 |
(6) C13 |
|