product brand name
|
SENTRON
|
product designation
|
3KC transfer switching equipment
|
design of the product
|
manually operated
|
display version for switch b indicator door-coupling rotary operating mechanism
|
I ON- O OFF- II ON
|
design of the actuating element
|
Without handle
|
design of handle
|
without
|
type of the driving mechanism
|
Front operating mechanism
|
type of the driving mechanism motor drive
|
No
|
General technical data
|
number of poles
|
3
|
type of device
|
fixed mounting
|
size of switch disconnector
|
5
|
mechanical service life (operating cycles) for function sequence O-I-O typical
|
6 000
|
I2t value
|
|
● with closed switch for combination switch + fuse at 500 V maximum
|
25 960 000 A2·s
|
● of the fuse at 415 V maximum permissible
|
34 800 005 A2·s
|
● of the fuse at 500 V maximum permissible
|
34 800 005 A2·s
|
● with closed switch for combination switch + fuse at 415 V maximum
|
25 960 000 A2·s
|
b of the switch operating mechanism
|
at the left end
|
overvoltage category
|
IV
|
degree of pollution
|
3
|
insulation voltage
|
|
● rated value
|
1 000 V
|
Protection class
|
protection class IP
|
IP00
|
protection class IP
|
|
● with closed switch with cover or cable lug cover
|
IP20
|
● on the front
|
IP00
|
Dissipation
|
power loss [W]
|
|
● with conventional rated thermal current per device
|
210 W
|
Main circuit
|
operating power
|
|
● at AC-23 A at 400 V at 50/60 Hz rated value
|
400 kW
|
● at AC-23 A at 500 V rated value
|
560 kW
|
operational current rated value
|
1 250 A
|
Auxiliary circuit
|
number of connected NC contacts for auxiliary contacts
|
0
|
number of connected NO contacts for auxiliary contacts
|
0
|
number of connected CO contacts for auxiliary contacts
|
0
|
number of CO contacts for auxiliary contacts
|
0
|
number of NC contacts for auxiliary contacts
|
16
|
number of NO contacts for auxiliary contacts
|
16
|
suitability for use main switch
|
Yes
|
suitability for use switch disconnector
|
Yes
|
suitability for use EMERGENCY OFF switch
|
Yes
|
suitability for use safety switch
|
Yes
|
suitability for use maintenance/repair switch
|
Yes
|
product feature interlock
|
No
|
product extension auxiliary switch
|
Yes
|
product extension optional motor drive
|
No
|
product extension optional voltage trigger
|
No
|
Short circuit
|
short-circuit current making capacity (Icm) for switch disconnector
|
|
● at 415 V AC without fuse b according to IEC 60947-6-1 rated value minimum
|
105 kA
|
● at 690 V AC without fuse b according to IEC 60947-3 rated value minimum
|
105 kA
|
conditional short-circuit current with line-side fuse protection
|
|
● at 415 V by gG fuse according to IEC 60947-6-1 rated value
|
80 kA
|
● at 415 V by gG fuse rated value
|
80 kA
|
● at 500 V by gG fuse according to IEC 60947-3 rated value
|
80 kA
|
Connections
|
type of connectable conductor cross-sections for aluminum conductor stranded with lug
|
1x (120 ... 300 mm2), 2x (95 ... 300 mm2)
|
type of connectable conductor cross-sections
|
|
● with combination of Al conductor+switch
|
680 A / 2x 300 mm2
|
● for copper busbar
|
2x (60 x10 mm2)
|
type of connectable conductor cross-sections for copper conductor
|
|
● stranded with lug according to DIN 46234
|
1x (120 ... 240 mm2), 2x (95 ... 240 mm2)
|
● stranded with lug according to DIN 46235
|
1x (120 ... 240 mm2), 2x (95 ... 240 mm2)
|
type of electrical connection
|
|
● for main current circuit
|
busbar connection
|