詳細(xì)參數(shù) | |||
---|---|---|---|
品牌 | 力士樂 | 型號 | KDA3.2-150-3-A00-U1 |
加工定制 | 否 |
KDA3.2-150-3-A00-U1力士樂INDRAMAT伺服器維修
維修力士樂驅(qū)動器HCS02.1E-W0012-A-03-NNNN+CSH01.1C-ET-ENS-NNN-NNN-NN-S,Rexroth力士樂驅(qū)動HCS02.1E-W0012,HCS02.1E-W0054-R-03-NNNN,HCS02.1E-W0028-R-03-NNNN,HCS02.1E-W0028-R-04-NNNN,HCS02.1E-W0028-R-05-NNNN,HCS02.1E-W0012-R-03-NNNN,HCS01.1N-W0070-R-07-NNNN,HMS01.1N-W0150-R-07-NNNN,CML40.1-NP-220-NA-NNNN-NW,MSK101D-0300-NN-M1-BG2-NNNN
HCS01.1E-W0018-A-03-B-ET-EC-NN
HCS01.1E-W0018-A-03-B-ET-EC-NN
KDA3.2-150-3-A00-U1
KDA3.2-150-3-A00-U1
HCS02.1E-W0012-A-03-NNNN
HCS02.1E-W0012-A-03-NNNN
VCP11.2DWN-003-NN-NN-PW
VCP11.2DWN-003-NN-NN-PW
MSK060C-0600-NN-M1-UP1-NNNN
HCS02.1E-W0012-A-03-NNNN
HCS02.1E-W0012-A-03-NNNN
HCS02.1E-W0028-A-03-NNNN
HCS02.1E-W0028-A-03-NNNN
HCS02.1E-W0012-A-03-NNNN
HCS02.1E-W0012-A-03-NNNN
力士樂REXROTH伺服驅(qū)動器1、示波器檢查驅(qū)動器的電流監(jiān)控輸出端時,發(fā)現(xiàn)它全為噪聲,無法讀出;故障原因:電流監(jiān)控輸出端沒有與交流電源相隔離(變壓器)。處理方法:可以用直流電壓表檢測觀察。2、電機一個方向上比另一個方向跑得快;(1) 故障原因:無刷電機的相位搞錯。處理方法:檢測或查出正確的相位。(2) 故障原因:在不用于測試時,測試/偏差開關(guān)打在測試位置。處理方法:將測試/偏差開關(guān)打在偏差位置。(3) 故障原因:偏差電位器位置不正確。處理方法:重新設(shè)定。3、電機失速;(1) 故障原因:速度反饋的極性搞錯。處理方法:可以嘗試以下方法。a. 如果可能,將位置反饋極性開關(guān)打到另一位置。(某些驅(qū)動器上可以)b. 如使用測速機,將驅(qū)動器上的TACH+和TACH-對調(diào)接入。c. 如使用編碼器,將驅(qū)動器上的ENC A和ENC B對調(diào)接入。d. 如在HALL速度模式下,將驅(qū)動器上的HALL-1和HALL-3對調(diào),再將Motor-A和Motor-B對調(diào)接好。(2) 故障原因:編碼器速度反饋時,編碼器電源失電。處理方法:檢查連接5V編碼器電源。確保該電源能提供足夠的電流。如使用外部電源,確保該電壓是對驅(qū)動器信號地的。