最近中文字幕在线mv视频在线,中文字幕无码家庭乱欲,一区二区伊人久久大杳蕉 ,亚洲综合国产一区,夜夜爽www

資訊詳情
西門子SIPLUS CPU317F-2PN/DP主機(jī)模塊
發(fā)布者:a5824085  發(fā)布時間:2016-05-16 19:37:04

西門子SIPLUS CPU317F-2PN/DP主機(jī)模塊

銷售訂貨號:

6AG1317-2FK14-2AB0
SIPLUS S7-300 CPU317F-2PN/DP -25 ... +60 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7317-2FK14-0AB0 . CENTRAL PROCESSING UNIT WITH 1.5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD REQUIRED
6AG1317-2FK14-2AY0
SIPLUS S7-300 CPU317F-2PN/DP -25 ... +60 DEGREES C CONFORMITY WITH EN50155 T1 CAT 1 CL A/B BASED ON 6ES7317-2FK14-0AB0 . CENTRAL PROCESSING UNIT WITH 1.5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD REQUIRED

西門子S7-300PLC  優(yōu)勢價格  現(xiàn)貨銷售

 聯(lián)系人 :卜社幫( 銷售經(jīng)理 )24小時服務(wù)熱線 :18202105796
電話( Tel ): 021-60641323   傳真(Fax):021-57872917
工作QQ: 2880583563 
地址( Add ):上海市松江區(qū)弘翔路58弄195號

西門子SIPLUS CPU317F-2PN/DP主機(jī)模塊   產(chǎn)品簡介:

具有大容量程序存儲器和較大數(shù)量結(jié)構(gòu)的故障安全 CPU,用于在具有較高安全要求的工廠中建立故障安全自動化系統(tǒng)
符合 IEC 61508 的 SIL 3、ISO 13849-1 的 PL e 以及 EN 954-1 的 Cat 4 安全要求
故障安全 I/O 模塊可通過集成式 PROFINET 接口 (PROFIsafe) 在本地連接和/或通過集成式 PROFIBUS DP 接口 (PROFIsafe) 進(jìn)行連接
也可以集中連接 ET 200M 的故障安全 I/O 模塊
可集中運(yùn)行或在本地運(yùn)行非安全應(yīng)用的標(biāo)準(zhǔn)模塊
經(jīng)由 PROFINET 的基于組件的自動化 (CBA)
PROFINET I/O 控制器,用于在 PROFINET 上運(yùn)行分布式 I/O
用于 2 端口交換機(jī)的 PROFINET 接口
PROFINET 代理,用于基于組件的自動化(CBA)中的 PROFIBUS DP 智能設(shè)備
CPU 的運(yùn)行需要 SIMATIC 微型存儲卡。
注:
SIPLUS extreme 產(chǎn)品基于 SIMATIC 標(biāo)準(zhǔn)產(chǎn)品。此處的內(nèi)容摘自相關(guān)的標(biāo)準(zhǔn)產(chǎn)品。增加了與 SIPLUS extreme 相關(guān)的信息
Area of application
CPU 317F-2 PN/DP 允許對設(shè)備實施更為復(fù)雜的故障安全型自動化系統(tǒng),以滿足提高的安全要求(特別是制造自動化方面的安全要求)。
可在 SIMATIC S7-300 中用作一個 PROFINET IO 控制器和一個標(biāo)準(zhǔn) PROFIBUS DP 主站。CPU 317F-2 PN/DP 也可用作分布式智能從站(DP 從站)。
可以通過兩個集成的接口連接包含故障安全型 I/O 模塊的分布式 I/O 站。ET 200M 的故障安全型 I/O 模塊還可以安裝在安全相關(guān)的中央組態(tài)中。
基于 PROFIsafe 行規(guī)執(zhí)行 F-CPU 和故障安全型 I/O 模塊之間的安全通訊。
CPU 運(yùn)行需要 SIMATIC 微型存儲卡(MMC 卡)。
Design
CPU 317F-2 PN/DP 安裝有:
微處理器:
處理器完成每條二進(jìn)制指令的執(zhí)行時間約為 25 ns,每條浮點數(shù)運(yùn)算約為 160 ns。
存儲器:
1.5 MB 高速工作存儲器,用于與安全相關(guān)的程序段和標(biāo)準(zhǔn)程序段;對于與安全相關(guān)的程序段,則必須考慮增加存儲空間(5倍以上)。SIMATIC 微型存儲卡(最大 8 MB)作為程序的裝載存儲器,還允許將項目(包括符號和注釋)存儲在 CPU 中。
靈活的擴(kuò)展能力:
多達(dá) 32 個模塊,(4 層結(jié)構(gòu))
組合 MPI/DP 接口:
第1個內(nèi)置 DP 接口可以最多同時建立 16 個與 S7-300/400 或與 PG、PC、OP 的連接。在這些連接中,始終分別為 PG 和 OP 各保留一個連接。
MPI 可以通過“全局?jǐn)?shù)據(jù)通訊”與最多32個CPU組建簡單的網(wǎng)絡(luò)。
該接口可從MPI接口重新設(shè)置為DP接口。DP 接口可用作 DP 主站或 DP 從站運(yùn)行。
PROFIBUS DP 接口:
全面支持 PROFIBUS DP V1 標(biāo)準(zhǔn)。這將增加 DP V1 標(biāo)準(zhǔn)從站在診斷和參數(shù)賦值能力的范圍。
以太網(wǎng)接口:
CPU 317F-2 PN/DP 的第 2 個內(nèi)置接口是一個基于以太網(wǎng) TCP/IP 的 PROFINET 接口,帶有雙端口交換機(jī)。它支持下列協(xié)議:
S7通訊用于在SIMATIC控制器間進(jìn)行數(shù)據(jù)通訊;
通過 STEP 7 進(jìn)行編程、啟動和診斷的 PG/OP 通訊;
與HMI和SCADA連接的PG/OP通訊;
基于PROFInet和SIMATIC NET OPC服務(wù)器的開放式TCP/IP通訊,用于與其它控制器和帶單獨CPU的I/O設(shè)備進(jìn)行通訊.
Functions
密碼保護(hù);
通過密碼,可保護(hù)用戶程序免受未經(jīng)授權(quán)的訪問。
診斷緩沖器;
最后 500 個錯誤和中斷事件保存在緩沖器中,供診斷用。
免維護(hù)數(shù)據(jù)備份;
當(dāng)電源發(fā)生故障時,CPU 將自動保存全部數(shù)據(jù),當(dāng)電源恢復(fù)后,這些數(shù)據(jù)將保持不變。
可參數(shù)化的特性
可以使用 STEP 7 對 S7 的組態(tài)、屬性以及 CPU 的響應(yīng)進(jìn)行參數(shù)設(shè)置:
多點接口 (MPI);
確定節(jié)點地址。
重新啟動/周期性能特性;
設(shè)置最大周期時間和負(fù)載
時鐘存儲器:
設(shè)置地址
保護(hù)級別;
訪問程序與數(shù)據(jù)的權(quán)限定義
系統(tǒng)診斷;
確定處理與診斷消息的范圍
監(jiān)視器中斷;
定義周期時間
實時中斷;
設(shè)定起始日期、起始時間和間隔周期。
PROFIBUS DP 主站/從站接口;
用戶定義的地址分配,適用于分布式 I/O 
顯示功能與信息功能
狀態(tài)和錯誤指示;
發(fā)光二極管顯示,例如,硬件、編程、定時器、I/O、總線故障以及運(yùn)行狀態(tài),如RUN、STOP、start-up.。
測試功能; 
使用編程器顯示程序執(zhí)行過程中的信號狀態(tài),可以不通過用戶程序修改過程變量,以及輸出堆棧內(nèi)容。
信息功能;
通過編程器以文本形式為用戶提供存儲能力信息、CPU的運(yùn)行模式,以及主存儲器和裝載存儲器當(dāng)前的使用情況、當(dāng)前的循環(huán)時間和診斷緩沖區(qū)的內(nèi)容。
集成通信功能
編程器/OP 通信
全局?jǐn)?shù)據(jù)通信
S7 基本通信
S7 通信
通過TCP/IP進(jìn)行開放通訊
PROFINET CBA(基于組件的自動化)
Web 服務(wù)器
數(shù)據(jù)記錄路由
通信
中央控制器和分布式站點之間的安全通訊和標(biāo)準(zhǔn)通訊在 PROFIBUS DP 和/或 PROFINET 上進(jìn)行。特殊開發(fā)的PROFIsafe支持在標(biāo)準(zhǔn)數(shù)據(jù)報文中傳送具有安全功能的用戶數(shù)據(jù)。無需其它硬件組件,例如特殊安全總線。所需的軟件既可以作為一個操作系統(tǒng)的擴(kuò)展功能集成在硬件組件中,也可以作為一個軟件塊裝載到 CPU 中。
操作模式
F-CPU 的安全功能包含在 CPU 的 F 程序中以及故障安全信號模塊中。信號模塊采用差異分析方法和測試信號注入技術(shù)來監(jiān)視輸入和輸出信號。
CPU通過周期性自檢、命令測試以及基于邏輯和時間的程序執(zhí)行檢測,檢查控制器運(yùn)行的正確性。此外,通過“活躍標(biāo)志(sign-of-life)”請求,還可以對 I/O 進(jìn)行檢測。
當(dāng)系統(tǒng)診斷出一個故障時,系統(tǒng)將進(jìn)入安全狀態(tài)。
運(yùn)行 CPU 317F-2 PN/DP 無需 F 運(yùn)行版授權(quán)。
編程
CPU 317F-2 PN/DP 的編程方法與 SIMATIC S7 系統(tǒng)的編程方法相同。通過諸如 STEP 7 編程工具可創(chuàng)建非安全型用戶程序。
選件包 SIMATIC S7 Distributed Safety (Classic) 和 SIMATIC Safety Advanced V12 (TIA Portal V12)
STEP 7 選件包“SIMATIC S7 Distributed Safety”(Classic) 或 SIMATIC Safety Advanced V12 (TIA Portal V12) 用于對與安全型程序段進(jìn)行編程。選件包中包括所有用來創(chuàng)建 F 程序的所有功能和塊。
具有安全功能的 F 程序以 F_FBD 或 F-LAD 方式進(jìn)行連接,或利用 F 功能庫中的特殊功能數(shù)據(jù)塊進(jìn)行連接。 使用 F FBD 或 F LAD 可簡化工廠的
組態(tài)與編程,也因與特定工廠無關(guān)的統(tǒng)一表示形式而簡化了驗收測試。無須使用其它工具,程序員就可以對安全型應(yīng)用進(jìn)行組態(tài)。

西門子SIPLUS CPU317F-2PN/DP主機(jī)模塊   技術(shù)參數(shù):

Order number

6AG1317-2FK14-2AB0

6AG1317-2FK14-2AY0

SIPLUS S7-300 CPU317F-2PN/DP

SIPLUS S7-300 CPU317F-2PN/DP EN50155

General information

 

 

Engineering with

 

 

  • ● Programming package

STEP 7 V 5.5 or higher, Distributed Safety V 5.4 SP4

STEP 7 V 5.5 or higher, Distributed Safety V 5.4 SP4

Supply voltage

 

 

Rated value (DC)

  • ● 24 V DC

Yes

Yes

Power loss

 

 

Power loss, typ.

4.65 W

4.65 W

Memory

 

 

Work memory

 

 

  • ● integrated

1 536 kbyte

1 536 kbyte

  • ● Size of retentive memory for retentive data blocks

256 kbyte

256 kbyte

Load memory

 

 

  • ● Plug-in (MMC), max.

8 Mbyte

8 Mbyte

CPU processing times

 

 

for bit operations, typ.

0.025 μs

0.025 μs

for word operations, typ.

0.03 μs

0.03 μs

for fixed point arithmetic, typ.

0.04 μs

0.04 μs

for floating point arithmetic, typ.

0.16 μs

0.16 μs

Counters, timers and their retentivity

 

 

S7 counter

 

 

  • ● Number

512

512

IEC counter

 

 

  • ● present

Yes

Yes

S7 times

 

 

  • ● Number

512

512

IEC timer

 

 

  • ● present

Yes

Yes

Data areas and their retentivity

 

 

Flag

 

 

  • ● Number, max.

4 096 byte

4 096 byte

Address area

 

 

I/O address area

 

 

  • ● Inputs

8 192 byte

8 192 byte

  • ● Outputs

8 192 byte

8 192 byte

Process image

 

 

  • ● Inputs, adjustable

8 192 byte

8 192 byte

  • ● Outputs, adjustable

8 192 byte

8 192 byte

Time of day

 

 

Clock

 

 

  • ● Hardware clock (real-time clock)

Yes

Yes

Operating hours counter

 

 

  • ● Number

4

4

1. Interface

 

 

Interface type

Integrated RS 485 interface

Integrated RS 485 interface

Physics

RS 485

RS 485

Functionality

 

 

  • ● MPI

Yes

Yes

  • ● DP master

Yes

Yes

  • ● DP slave

Yes

Yes

  • ● Point-to-point connection

No

No

DP master

 

 

  • ● Number of DP slaves, max.

124

124

2. Interface

 

 

Interface type

PROFINET

PROFINET

Physics

Ethernet RJ45

Ethernet RJ45

Interface types

 

 

  • ● Number of ports

2

2

Functionality

 

 

  • ● MPI

No

No

  • ● DP master

No

No

  • ● DP slave

No

No

  • ● PROFINET IO Controller

Yes; Also simultaneously with IO-Device functionality

Yes; Also simultaneously with IO-Device functionality

  • ● PROFINET IO Device

Yes; Also simultaneously with IO Controller functionality

Yes; Also simultaneously with IO Controller functionality

  • ● PROFINET CBA

Yes

Yes

Isochronous mode

 

 

Isochronous operation (application synchronized up to terminal)

Yes; Via PROFIBUS DP or PROFINET interface

Yes; Via PROFIBUS DP or PROFINET interface

Communication functions

 

 

PG/OP communication

Yes

Yes

Data record routing

Yes

Yes

Global data communication

 

 

  • ● supported

Yes

Yes

S7 basic communication

 

 

  • ● supported

Yes

Yes

S7 communication

 

 

  • ● supported

Yes

Yes

S5 compatible communication

 

 

  • ● supported

Yes; via CP and loadable FC

Yes; via CP and loadable FC

Open IE communication

 

 

  • ● TCP/IP

Yes; via integrated PROFINET interface and loadable FBs

Yes; via integrated PROFINET interface and loadable FBs

  • — Number of connections, max.

16

16

  • ● ISO-on-TCP (RFC1006)

Yes; via integrated PROFINET interface and loadable FBs

Yes; via integrated PROFINET interface and loadable FBs

  • — Number of connections, max.

16

16

  • ● UDP

Yes; via integrated PROFINET interface and loadable FBs

Yes; via integrated PROFINET interface and loadable FBs

  • — Number of connections, max.

16

16

Web server

 

 

  • ● supported

Yes

Yes

Number of connections

 

 

  • ● overall

32

32

Ambient conditions

 

 

Ambient temperature during operation

 

 

  • ● min.

-25 °C; = Tmin

-25 °C; = Tmin

  • ● max.

60 °C; = Tmax

60 °C; = Tmax; the rated temperature range of -25 ... +55 °C (T1) applies for the use on railway vehicles according to EN50155

Ambient temperature during storage/transportation

 

 

  • ● min.

-40 °C

-40 °C

  • ● max.

70 °C

70 °C

Extended ambient conditions

 

 

  • ● relative to ambient temperature-atmospheric pressure-installation altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

Relative humidity

 

 

  • — With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation

Resistance

 

 

  • — against biologically active substances / conformity with EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres!

  • — against chemically active substances / conformity with EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • — against mechanically active substances / conformity with EN 60721-3-3

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

Configuration

 

 

Programming

 

 

Programming language

 

 

  • — LAD

Yes

Yes

  • — FBD

Yes

Yes

  • — STL

Yes

Yes

  • — SCL

Yes

Yes

  • — CFC

Yes

Yes

  • — GRAPH

Yes

Yes

  • — HiGraph®

Yes

Yes

Know-how protection

 

 

  • ● User program protection/password protection

Yes

Yes

  • ● Block encryption

Yes; With S7 block Privacy

Yes; With S7 block Privacy

Dimensions

 

 

Width

40 mm

40 mm

Height

125 mm

125 mm

Depth

130 mm

130 mm

Weights

 

 

Weight, approx.

340 g

340 g


版權(quán)聲明:工控網(wǎng)轉(zhuǎn)載作品均注明出處,本網(wǎng)未注明出處和轉(zhuǎn)載的,是出于傳遞更多信息之目的,并不意味 著贊同其觀點或證實其內(nèi)容的真實性。如轉(zhuǎn)載作品侵犯作者署名權(quán),或有其他諸如版權(quán)、肖像權(quán)、知識產(chǎn)權(quán)等方面的傷害,并非本網(wǎng)故意為之,在接到相關(guān)權(quán)利人通知后將立即加以更正。聯(lián)系電話:0571-87774297。